Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
J Small Anim Pract ; 64(11): 669-679, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37452675

RESUMO

OBJECTIVES: To describe the change in the caudal vena cava to aorta ratio (CVC:Ao) ratio during fluid resuscitation of circulatory shock in dogs and compare these results with those of the physical examination and blood lactate. MATERIALS AND METHODS: Perfusion parameters and blood lactate were recorded at admission. An abdominal point-of-care ultrasound protocol was performed, during which the caudal vena cava to aorta ratio was measured on the spleno-renal view. Measurements were performed within 5 minutes before and after a 10 mL/kg crystalloid fluid bolus. Investigators were not blinded to therapeutic interventions. RESULTS: Twenty-nine dogs with physical signs of circulatory shock were enrolled. Caudal vena cava to aorta ratios were below reference interval in 28 of 29 dogs. After bolus administration, median caudal vena cava diameter increased by 0.14 cm (0.69 to 0.83 cm) and median aorta diameter increased by 0.03 cm (0.87 to 0.90 cm) and caudal vena cava to aorta ratio returned to within reference range in 65% of dogs (13/29). Bolus administration was associated with an increase in median caudal vena cava to aorta ratio of 0.10 (95% CI:0.05 to 0.16, P=0.0005). Blood lactate did not change significantly. Heart rate and capillary refill time decreased significantly after fluid bolus (heart rate: estimate=-19 bpm, 95% CI:-30 to -8, P=0.002; capillary refill time: estimate=-1.0 s, 95% CI:-1.3 to -0.7, P < 0.0001). CLINICAL SIGNIFICANCE: In this population of dogs with circulatory shock, the caudal vena cava to aorta ratio significantly increased after a fluid bolus. Future studies that implement blinding of the outcome assessors are warranted to confirm these findings.


Assuntos
Aorta , Hidratação , Cães , Animais , Aorta/diagnóstico por imagem , Hidratação/veterinária , Veia Cava Inferior/diagnóstico por imagem , Ultrassonografia/veterinária , Lactatos
2.
Nat Commun ; 12(1): 3283, 2021 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-34078889

RESUMO

The anomalous Hall effect (AHE) is an intriguing transport phenomenon occurring typically in ferromagnets as a consequence of broken time reversal symmetry and spin-orbit interaction. It can be caused by two microscopically distinct mechanisms, namely, by skew or side-jump scattering due to chiral features of the disorder scattering, or by an intrinsic contribution directly linked to the topological properties of the Bloch states. Here we show that the AHE can be artificially engineered in materials in which it is originally absent by combining the effects of symmetry breaking, spin orbit interaction and proximity-induced magnetism. In particular, we find a strikingly large AHE that emerges at the interface between a ferromagnetic manganite (La0.7Sr0.3MnO3) and a semimetallic iridate (SrIrO3). It is intrinsic and originates in the proximity-induced magnetism present in the narrow bands of strong spin-orbit coupling material SrIrO3, which yields values of anomalous Hall conductivity and Hall angle as high as those observed in bulk transition-metal ferromagnets. These results demonstrate the interplay between correlated electron physics and topological phenomena at interfaces between 3d ferromagnets and strong spin-orbit coupling 5d oxides and trace an exciting path towards future topological spintronics at oxide interfaces.

3.
Opt Express ; 29(8): 11445-11452, 2021 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-33984923

RESUMO

A phase sensing system fitted to the control of coherent laser beam array of large cross section is experimented. It is based on the use of a fiber bundle that collects a weak part of the synthetic wavefront, that scales it down (1/40) and that reshapes it in a more compact arrangement (2D to 1D array). Then, the reconfigured beam array can be analyzed by a small footprint system making the large laser beam array easier to phase-lock. The discrete laser array wavefront transmitted by the meter long fiber bundle was stabilized thanks to a multiple arm servo loop. Laser array phase locking was further ensured by random scattering through a diffuser, associated to an alternating projection algorithm. Six fiber laser beams constituting a 110 mm diameter synthetic aperture, were phase-locked with λ/16 accuracy.

4.
J Small Anim Pract ; 62(4): 265-271, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33346390

RESUMO

OBJECTIVES: To prospectively describe the impact of gas flow rate and temperature on dog's tolerance of high-flow nasal oxygen therapy during recovery from anaesthesia, hypothesizing that higher flow rates and temperatures will decrease tolerance. MATERIALS AND METHODS: Twelve non-dyspnoeic client-owned dogs recovering from general anaesthesia were included in this study. After extubation, a nasal cannula was positioned and high-flow nasal oxygen therapy was initiated. Two flow rates (two or four time the theoretical minute ventilation: HF2 and HF4), each of them combined with two temperatures (31 and 37°C: T31 and T37), were randomly applied (four conditions per dog). For each condition, cardiovascular and respiratory parameters (heart rate, respiratory rate, systolic arterial blood pressure and pulse oximeter oxygen saturation), sedation score and tolerance score were recorded at initiation (T0 ) and after 10 minutes of accommodation (T10 ). RESULTS: Sedation scores were not significantly different between the four conditions. Cardiovascular and respiratory parameters were not significantly different between any condition at both T0 and T10 . Tolerance scores were good and not significantly different between any flow rate or temperature (HF2-T31: 4 (2-4), HF4-T31: 4 (2-4), HF2-T37: 4 (2-4), HF4-T37: 4 (1-4)). CLINICAL SIGNIFICANCE: The gas flow rates and temperatures studied have no impact on tolerance during the recovery period of non-dyspnoeic dogs, and high-flow nasal cannula is well tolerated. Further studies are required to confirm these results in dyspnoeic dogs.


Assuntos
Doenças do Cão , Oxigenoterapia , Animais , Cânula , Doenças do Cão/terapia , Cães , Dispneia/veterinária , Oxigênio , Oxigenoterapia/veterinária , Temperatura
5.
J Small Anim Pract ; 60(11): 656-662, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31313305

RESUMO

OBJECTIVES: To describe the use, effectiveness and tolerance of high-flow oxygen therapy in dyspnoeic dogs. MATERIALS AND METHODS: Prospectively, dogs in acute respiratory distress admitted to an intensive care unit between January and May 2018 that failed to respond to nasal oxygen therapy and medical stabilisation after 30 minutes were transitioned to high-flow oxygen therapy. High-flow oxygen therapy, delivered an inspired oxygen fraction of 100% using an air/oxygen blender, active humidifier, single warmed tube and specific nasal cannula. Respiratory rate, pulse oximetry (SpO2 ), heart rate and a tolerance score were assessed every 15 minutes from T0 (under nasal oxygen) to 1 hour (T60 ), and PaO2 and PaCO2 at T0 and T60 . Complications were recorded for each dog. RESULTS: Eleven dogs were included. At T60 , PaO2 , flow rate and SpO2 were significantly greater than at T0 (171 ± 123 versus 73 ± 24 mmHg; P=0.015; 18 ±12 L/minute versus 3.2 ± 2.0 L/minute, P<0.01; 97.7 ±2.3% versus 91.6 ±7.2%, P=0.03, respectively). There was no significant difference in PaCO2 , respiratory rate or heart rate between T0 and T60 . Tolerance was excellent, and there were no complications. CLINICAL SIGNIFICANCE: High-flow oxygen therapy improves markers of oxygenation in dyspnoeic dogs and is an effective means to deliver oxygen with comfort and minimal complications.


Assuntos
Oximetria/veterinária , Oxigenoterapia/veterinária , Animais , Cânula , Oxigênio , Projetos Piloto , Estudos Prospectivos
6.
Opt Express ; 27(12): 17311-17321, 2019 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-31252943

RESUMO

We report experimental results, showing that the Kerr beam self-cleaning of many low-order modes in a graded-index multimode fiber can be controlled thanks to optimized wavefront shaping of the coherent excitation beam. Adaptive profiling of the transverse input phase was utilized for channeling the launched power towards a specific low-order fiber mode, by exploiting nonlinear coupling among all guided modes. Experiments were carried out with 7 ps pulses at 1064 nm injected in a five meters long multimode fiber operating in the normal dispersion regime. Optimized Kerr beam self-cleaning of five different LP modes is reported, with a power threshold that increases with the mode order.

7.
Nat Commun ; 9(1): 407, 2018 01 29.
Artigo em Inglês | MEDLINE | ID: mdl-29379023

RESUMO

In LaAlO3/SrTiO3 heterostructures, a gate tunable superconducting electron gas is confined in a quantum well at the interface between two insulating oxides. Remarkably, the gas coexists with both magnetism and strong Rashba spin-orbit coupling. However, both the origin of superconductivity and the nature of the transition to the normal state over the whole doping range remain elusive. Here we use resonant microwave transport to extract the superfluid stiffness and the superconducting gap energy of the LaAlO3/SrTiO3 interface as a function of carrier density. We show that the superconducting phase diagram of this system is controlled by the competition between electron pairing and phase coherence. The analysis of the superfluid density reveals that only a very small fraction of the electrons condenses into the superconducting state. We propose that this corresponds to the weak filling of high-energy dxz/dyz bands in the quantum well, more apt to host superconductivity.

8.
J Small Anim Pract ; 59(3): 174-182, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28960319

RESUMO

OBJECTIVES: The aims of this study were to describe a method for the sonographic assessment of volaemia, to determinate inter- and intra-operator variability and to assess the ability to detect blood loss after blood donation in healthy dogs. MATERIALS AND METHODS: The left kidney was identified in a spleno-renal view, and transverse views of the caudal vena cava and aorta were obtained in 12 dogs. Vessel diameters were measured in B-mode, in duplicate by two operators, and the caudal vena cava:aorta ratio was calculated. Intra- and inter-operator variabilities were assessed using a Bland-Altman method by plotting the differences between the repeated measurements obtained from the same subject by the same operator and by the two operators against their means. Before and after blood donation measurements were compared using paired t-tests or one-sample t-tests, if appropriate. RESULTS: Intra- and inter-operator variability was within the limit of agreement for the vast majority of measurements. After a blood donation of 9·8 ±2·2 mL/kg, the mean aorta measurements were not significantly different from those obtained before blood donation (1·11 versus 1·10, P=0·28), whereas the mean caudal vena cava measurements and caudal vena cava:aorta ratios were significantly lower (1·28 versus 1·01, P<0·0001; 1·17 versus 1·01, P=0·0001, respectively). CLINICAL SIGNIFICANCE: The low intra- and inter-operator variabilities in the caudal vena cava, aorta and caudal vena cava:aorta ratio measurements support their reliability and operator independency. The sonographic assessment of volaemia appears to be a promising non-invasive, repeatable point-of-care ultrasound protocol for assessment and monitoring of blood loss. Further studies are needed to assess the sonographic assessment of volaemia protocol in spontaneously bleeding dogs.


Assuntos
Aorta/diagnóstico por imagem , Doadores de Sangue , Volume Sanguíneo/veterinária , Cães/fisiologia , Veia Cava Inferior/diagnóstico por imagem , Animais , Cães/anatomia & histologia , Feminino , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Ultrassonografia/veterinária
9.
Opt Express ; 25(19): 22219-22227, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041536

RESUMO

We study a coupled cavity laser configuration where a passively Q-switched Nd:YAG microchip laser is combined with an extended cavity, including a doped multimode fiber. For appropriate coupling levels with the extended cavity, we observed that beam self-cleaning was induced in the multimode fiber thanks to nonlinear modal coupling, leading to a quasi-single mode laser output. In the regime of beam self-cleaning, laser pulse duration was reduced from 525 to 225 ps. We also observed a Q-switched mode-locked operation, where spatial self-cleaning was accompanied by far-detuned nonlinear frequency conversion in the active multimode fiber.

10.
Nature ; 549(7671): 252-256, 2017 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-28905889

RESUMO

Although ferromagnets have many applications, their large magnetization and the resulting energy cost for switching magnetic moments bring into question their suitability for reliable low-power spintronic devices. Non-collinear antiferromagnetic systems do not suffer from this problem, and often have extra functionalities: non-collinear spin order may break space-inversion symmetry and thus allow electric-field control of magnetism, or may produce emergent spin-orbit effects that enable efficient spin-charge interconversion. To harness these traits for next-generation spintronics, the nanoscale control and imaging capabilities that are now routine for ferromagnets must be developed for antiferromagnetic systems. Here, using a non-invasive, scanning single-spin magnetometer based on a nitrogen-vacancy defect in diamond, we demonstrate real-space visualization of non-collinear antiferromagnetic order in a magnetic thin film at room temperature. We image the spin cycloid of a multiferroic bismuth ferrite (BiFeO3) thin film and extract a period of about 70 nanometres, consistent with values determined by macroscopic diffraction. In addition, we take advantage of the magnetoelectric coupling present in BiFeO3 to manipulate the cycloid propagation direction by an electric field. Besides highlighting the potential of nitrogen-vacancy magnetometry for imaging complex antiferromagnetic orders at the nanoscale, these results demonstrate how BiFeO3 can be used in the design of reconfigurable nanoscale spin textures.

11.
J Vet Intern Med ; 31(5): 1420-1429, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28804957

RESUMO

BACKGROUND: When dogs are transfused, blood compatibility testing varies widely but may include dog erythrocyte antigen (DEA) 1 typing and rarely cross-matching. OBJECTIVES: Prospective study to examine naturally occurring alloantibodies against red blood cells (RBCs) and alloimmunization by transfusion using 2 antiglobulin-enhanced cross-match tests. ANIMALS: Eighty client-owned anemic, 72 donor, and 7 control dogs. METHODS: All dogs were typed for DEA 1 and some also for DEA 4 and DEA 7. Major cross-match tests with canine antiglobulin-enhanced immunochromatographic strip and gel columns were performed 26-129 days post-transfusion (median, 39 days); some dogs had an additional early evaluation 11-22 days post-transfusion (median, 16 days). Plasma from alloimmunized recipients was cross-matched against RBCs from 34 donor and control dogs. RESULTS: The 2 cross-match methods gave entirely concordant results. All 126 pretransfusion cross-match results for the 80 anemic recipients were compatible, but 54 dogs died or were lost to follow up. Among the 26 recipients with follow-up, 1 dog accidently received DEA 1-mismatched blood and became cross-match-incompatible post-transfusion. Eleven of the 25 DEA 1-matched recipients (44%) became incompatible against other RBC antigens. No naturally occurring anti-DEA 7 alloantibodies were detected in DEA 7- dogs. CONCLUSIONS AND CLINICAL IMPORTANCE: The antiglobulin-enhanced immunochromatographic strip cross-match and laboratory gel column techniques identified no naturally occurring alloantibodies against RBC antigens, but a high degree of post-transfusion alloimmunization in dogs. Cross-matching is warranted in any dog that has been previously transfused independent of initial DEA 1 typing and cross-matching results before the first transfusion event.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/veterinária , Transfusão de Sangue/veterinária , Teste de Coombs/veterinária , Cães/imunologia , Animais , Anticorpos Anti-Idiotípicos/imunologia , Tipagem e Reações Cruzadas Sanguíneas/métodos , Eritrócitos/imunologia , Isoanticorpos/imunologia , Estudos Prospectivos
12.
Opt Express ; 25(5): 4783-4792, 2017 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-28380747

RESUMO

We experimentally demonstrate that Kerr spatial self-cleaning of a pulsed beam can be obtained in an amplifying multimode optical fiber. An input peak power of 500 W only was sufficient to produce a quasi-single-mode emission from the double-clad ytterbium doped multimode fiber (YMMF) with non-parabolic refractive index profile. We compare the self-cleaning behavior observed in the same fiber with loss and with gain. Laser gain introduces new opportunities to achieve spatial self-cleaning of light in multimode fibers at a relatively low power threshold.

13.
Opt Lett ; 42(7): 1293-1296, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28362752

RESUMO

We demonstrate far-detuned parametric frequency conversion processes in a few mode graded-index optical fibers pumped by a Q-switched picosecond laser at 1064 nm. Through a detailed analytical and numerical analysis, we show that the multiple sidebands are generated through a complex cascaded process involving inter-modal four-wave mixing. The resulting parametric wavelength detuning spans in the visible down to 405 nm and in the near-infrared up to 1355 nm.

14.
Mucosal Immunol ; 10(2): 460-469, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27220813

RESUMO

During influenza A virus (IAV) infection, changes in the lung's physical and immunological defenses predispose the host to bacterial superinfections. Invariant natural killer T (iNKT) cells are innate-like T lymphocytes that have beneficial or harmful functions during infection. We investigated the iNKT cells' role in a model of invasive pneumococcal superinfection. The use of Jα18-/- mice indicated that iNKT cells limited susceptibility to influenza-pneumococcal infection and reduced the lethal synergism. This role did not depend on immune-based anti-bacterial mechanisms. At the time of bacterial exposure, iNKT cells from IAV-experienced mice failed to produce antipneumococcal interferon-γ and adoptive transfer of fresh iNKT cells before Streptococcus pneumoniae challenge did not restore anti-bacterial host defenses. Impaired iNKT cell activation in superinfected animals was related to the IAV-induced immunosuppressive cytokine interleukin-10 (IL-10), rather than to an intrinsic functional defect. IL-10 dampened the activation of iNKT cells in response to pneumococci by inhibiting the production of IL-12 by pulmonary monocyte-derived dendritic cells. Neutralization of IL-10 restored iNKT cell activation and tends to increase resistance to secondary bacterial infection. Overall, iNKT cells have a beneficial role (upstream of bacterial colonization) in controlling influenza-pneumococcal superinfection, although they represent novel targets of immunosuppression at the time of bacterial challenge.


Assuntos
Vírus da Influenza A/imunologia , Interleucina-10/metabolismo , Pulmão/imunologia , Células T Matadoras Naturais/imunologia , Infecções por Orthomyxoviridae/imunologia , Infecções Pneumocócicas/imunologia , Streptococcus pneumoniae/imunologia , Animais , Anticorpos Neutralizantes/metabolismo , Células Cultivadas , Células Dendríticas/imunologia , Suscetibilidade a Doenças , Tolerância Imunológica , Imunidade Inata , Interleucina-10/imunologia , Interleucina-12/metabolismo , Pulmão/microbiologia , Pulmão/virologia , Ativação Linfocitária , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Receptores de Antígenos de Linfócitos T alfa-beta/genética , Superinfecção
15.
J Vet Intern Med ; 31(1): 69-80, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27911985

RESUMO

BACKGROUND: Leptospirosis in dogs is occasionally associated with a hemorrhagic syndrome, the pathophysiology of which is not fully understood. HYPOTHESIS/OBJECTIVES: To characterize hematologic, hemostatic, and thromboelastometric abnormalities in dogs with leptospirosis and to study their association with hemorrhagic diatheses and outcomes. ANIMALS: Thirty-five client-owned dogs. METHODS: A prospective observational single cohort study was conducted. Results from the CBC, coagulation tests (prothrombin, activated partial thromboplastin and thrombin times, fibrinogen, fibrin(ogen) degradation products, and D-dimer concentrations), rotational thromboelastometry (TEM), signalment, hemorrhagic diatheses, occurrence of disseminated intravascular coagulation (DIC) at admission, and survival to discharge were recorded. RESULTS: The most common hematologic and hemostatic abnormalities were anemia (30/35), thrombocytopenia (21/35), and hyperfibrinogenemia (15/35). Eight dogs were diagnosed with DIC. A normal TEM profile was found in 14 dogs, a hypercoagulable profile in 14 dogs, and a hypocoagulable profile in 7 dogs. The 8 dogs with hemorrhagic diatheses at admission had significantly decreased platelet counts (P = .037) and increased D-dimer concentrations (P = .015) compared with other dogs. Dogs with a hypocoagulable profile exhibited more hemorrhagic diatheses compared with the dogs that had normal and hypercoagulable profiles (P = .049). The mortality rate was lower in dogs with a hypercoagulable profile than in those with a hypocoagulable profile (21% vs 57%; P = .043). Disseminated intravascular coagulation was not a significant prognostic factor. CONCLUSIONS AND CLINICAL IMPORTANCE: Thromboelastometric parameters were altered in dogs with both hypercoagulable and hypocoagulable profiles. A hypocoagulable profile was significantly correlated with hemorrhagic diathesis and higher mortality rate.


Assuntos
Coagulação Intravascular Disseminada/veterinária , Doenças do Cão/mortalidade , Leptospirose/veterinária , Animais , Estudos de Coortes , Coagulação Intravascular Disseminada/sangue , Coagulação Intravascular Disseminada/complicações , Coagulação Intravascular Disseminada/mortalidade , Doenças do Cão/sangue , Cães , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , França , Hemostasia , Leptospirose/sangue , Leptospirose/complicações , Leptospirose/mortalidade , Masculino , Tempo de Tromboplastina Parcial/veterinária , Estudos Prospectivos , Análise de Sobrevida
16.
Adv Mater ; 29(9)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28036128

RESUMO

The magnetic-field-dependent spin ordering of strained BiFeO3 films is determined using nuclear resonant scattering and Raman spectroscopy. The critical field required to destroy the cycloidal modulation of the Fe spins is found to be significantly lower than in the bulk, with appealing implications for field-controlled spintronic and magnonic devices.

17.
Nat Mater ; 15(12): 1261-1266, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27571452

RESUMO

The spin-orbit interaction couples the electrons' motion to their spin. As a result, a charge current running through a material with strong spin-orbit coupling generates a transverse spin current (spin Hall effect, SHE) and vice versa (inverse spin Hall effect, ISHE). The emergence of SHE and ISHE as charge-to-spin interconversion mechanisms offers a variety of novel spintronic functionalities and devices, some of which do not require any ferromagnetic material. However, the interconversion efficiency of SHE and ISHE (spin Hall angle) is a bulk property that rarely exceeds ten percent, and does not take advantage of interfacial and low-dimensional effects otherwise ubiquitous in spintronic hetero- and mesostructures. Here, we make use of an interface-driven spin-orbit coupling mechanism-the Rashba effect-in the oxide two-dimensional electron system (2DES) LaAlO3/SrTiO3 to achieve spin-to-charge conversion with unprecedented efficiency. Through spin pumping, we inject a spin current from a NiFe film into the oxide 2DES and detect the resulting charge current, which can be strongly modulated by a gate voltage. We discuss the amplitude of the effect and its gate dependence on the basis of the electronic structure of the 2DES and highlight the importance of a long scattering time to achieve efficient spin-to-charge interconversion.

18.
Nat Commun ; 7: 11502, 2016 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-27143121

RESUMO

Organic electronics is emerging for large-area applications such as photovoltaic cells, rollable displays or electronic paper. Its future development and integration will require a simple, low-power organic memory, that can be written, erased and readout electrically. Here we demonstrate a non-volatile memory in which the ferroelectric polarisation state of an organic tunnel barrier encodes the stored information and sets the readout tunnel current. We use high-sensitivity piezoresponse force microscopy to show that films as thin as one or two layers of ferroelectric poly(vinylidene fluoride) remain switchable with low voltages. Submicron junctions based on these films display tunnel electroresistance reaching 1,000% at room temperature that is driven by ferroelectric switching and explained by electrostatic effects in a direct tunnelling regime. Our findings provide a path to develop low-cost, large-scale arrays of organic ferroelectric tunnel junctions on silicon or flexible substrates.

19.
Nat Phys ; 12(5): 484-492, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27158255

RESUMO

At interfaces between conventional materials, band bending and alignment are classically controlled by differences in electrochemical potential. Applying this concept to oxides in which interfaces can be polar and cations may adopt a mixed valence has led to the discovery of novel two-dimensional states between simple band insulators such as LaAlO3 and SrTiO3. However, many oxides have a more complex electronic structure, with charge, orbital and/or spin orders arising from strong Coulomb interactions between transition metal and oxygen ions. Such electronic correlations offer a rich playground to engineer functional interfaces but their compatibility with the classical band alignment picture remains an open question. Here we show that beyond differences in electron affinities and polar effects, a key parameter determining charge transfer at correlated oxide interfaces is the energy required to alter the covalence of the metal-oxygen bond. Using the perovskite nickelate (RNiO3) family as a template, we probe charge reconstruction at interfaces with gadolinium titanate GdTiO3. X-ray absorption spectroscopy shows that the charge transfer is thwarted by hybridization effects tuned by the rare-earth (R) size. Charge transfer results in an induced ferromagnetic-like state in the nickelate, exemplifying the potential of correlated interfaces to design novel phases. Further, our work clarifies strategies to engineer two-dimensional systems through the control of both doping and covalence.

20.
Nat Commun ; 7: 10718, 2016 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-26923332

RESUMO

The control of optical fields is usually achieved through the electro-optic or acousto-optic effect in single-crystal ferroelectric or polar compounds such as LiNbO3 or quartz. In recent years, tremendous progress has been made in ferroelectric oxide thin film technology-a field which is now a strong driving force in areas such as electronics, spintronics and photovoltaics. Here, we apply epitaxial strain engineering to tune the optical response of BiFeO3 thin films, and find a very large variation of the optical index with strain, corresponding to an effective elasto-optic coefficient larger than that of quartz. We observe a concomitant strain-driven variation in light absorption--reminiscent of piezochromism--which we show can be manipulated by an electric field. This constitutes an electrochromic effect that is reversible, remanent and not driven by defects. These findings broaden the potential of multiferroics towards photonics and thin film acousto-optic devices, and suggest exciting device opportunities arising from the coupling of ferroic, piezoelectric and optical responses.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...